Have a problem (of all things).
Got my new 710 set up on FT8 this morning, made some 40 m contacts. Got a message on Windows 11 Pro to update microphone. Did that, shut down the computer. Came back down a little later and fired everything back up. All worked correctly, I chose the band and frequency in WSJT (10 m, 28.074) and it immediately put my rig on that frequency. Made a couple calls and then I started getting a Rig Control Error "do you want to reconfigure the radio interface"? I've checked and rechecked, went to WalMart and bought a new USB A-B cable, all to no avail. I am copying signals just great. The freq. window shows 10m, circle is red, and where the actual frequency should be is 0.000 000 in red.
Settings: Yaesu FT-710
Com 6
8
1
Defajlt
PTT: CAT
Mode None (just now swapped to Data/Pkt to test, no difference)
Splilt Ops None.
Follow is the message I get:
Hamlib error: read_string_generic called, rxmax=129 direct=1, expected_len=1
read_string_generic(): Timed out 1.061 seconds after 0 chars, direct=1
rig_flush: called for serial device
read_string_generic called, rxmax=4095 direct=1, expected_len=1
cmd_str = VS;
write_block(): TX 3 bytes, method=2
0000 56 53 3b VS;
read_string_generic called, rxmax=129 direct=1, expected_len=1
read_string_generic(): Timed out 1.217 seconds after 0 chars, direct=1
4:newcat.c(10692):newcat_get_cmd returning(-5) Communication timed out
3:newcat.c(1804):newcat_get_vfo returning(-5) Communication timed out
Communication timed out
)
2:rig_get_vfo: elapsed=4447ms
2:rig.c(2947):rig_get_vfo returning(-5) Communication timed out
Communication timed out
Communication timed out
while testing getting current VFO
Timestamp: 2023-03-03T21:12:00.476Z
Can anyone tell me what I am not seeing?
Com 6
8
1
Defajlt
PTT: CAT
Mode None (just now swapped to Data/Pkt to test, no difference)
Splilt Ops None.
Follow is the message I get:
Hamlib error: read_string_generic called, rxmax=129 direct=1, expected_len=1
read_string_generic(): Timed out 1.061 seconds after 0 chars, direct=1
rig_flush: called for serial device
read_string_generic called, rxmax=4095 direct=1, expected_len=1
cmd_str = VS;
write_block(): TX 3 bytes, method=2
0000 56 53 3b VS;
read_string_generic called, rxmax=129 direct=1, expected_len=1
read_string_generic(): Timed out 1.217 seconds after 0 chars, direct=1
4:newcat.c(10692):newcat_get_cmd returning(-5) Communication timed out
3:newcat.c(1804):newcat_get_vfo returning(-5) Communication timed out
Communication timed out
)
2:rig_get_vfo: elapsed=4447ms
2:rig.c(2947):rig_get_vfo returning(-5) Communication timed out
Communication timed out
Communication timed out
while testing getting current VFO
Timestamp: 2023-03-03T21:12:00.476Z
Can anyone tell me what I am not seeing?
No comments:
Post a Comment
YAESU FT-710 discussions:
https://groups.io/g/ft-710
YAESU FT-710 website (CaSe Sensitive) shortcut.
bit.ly/FT710
bit.ly/ft-710
YAESU FT-710 discussions:
https://groups.io/g/ft-710
Yaesu website
www.bit.ly/yaesu2
www.bit.ly/yaesu4
https://www.yaesu.com/
https://groups.io/g/ft-710
.